BOARD ID="UNBFFB0" NAME="Adaptec AHA-1522 á1.03 4/12/93" MFR="Adaptec, Inc." CATEGORY="MSD" ; VERSION=1.20 LENGTH=175 ; BUSMASTER=50 AMPERAGE=1200 COMMENTS="AHA-1522 EISA Configuration File Version 1.00\n\n" HELP="Select the desired AHA-1522 configuration. Then use the configuration utility \"View Switches and Jumpers\" option to verify that the AHA-1522 jumpers have been set correctly for this configuration. The default configuration is identical with the factory jumper settings." JUMPER(5)=8 NAME="J5" JTYPE=PAIRED VERTICAL=NO REVERSE=YES LABEL=LOC(1-8) "DT" "BT" "M0" "M1" "SN" "DN" "R-" "R-" FACTORY=LOC(1-8) 01001100 INITVAL=LOC(1-8) xxxxxx00 JUMPER(6)=8 NAME="J6" JTYPE=PAIRED VERTICAL=NO REVERSE=YES LABEL=LOC(1-8) "SD" "SD" "SD" "IC" "IC" "DC" "DC" "SP" FACTORY=LOC(1-8) 11101000 JUMPER(7)=8 NAME="J7" JTYPE=PAIRED VERTICAL=NO REVERSE=YES LABEL=LOC(1-8) "FE" "DR" "DR" "DA" "DA" "I6" "I0" "DS" FACTORY=LOC(1-8) 11010100 JUMPER(8)=8 NAME="J8" JTYPE=PAIRED VERTICAL=NO REVERSE=YES LABEL=LOC(1-8) "DR" "D6" "D5" "D0" "DA" "D6" "D5" "D0" FACTORY=LOC(1-8) 00010001 JUMPER(9)=8 NAME="J9" JTYPE=PAIRED VERTICAL=NO REVERSE=YES LABEL=LOC(1-8) "I2" "I1" "I0" "I9" "AL" "J6" "J4" "BE" FACTORY=LOC(1-8) 01000111 ;GROUP="Host Adapter System Resources" TYPE="MSD" FUNCTION="Data Transfer " COMMENTS="This option allows the user to select whether AHA-1522 data transfer will be performed by Programmed I/O (default) or by 2nd Party DMA." CHOICE="\ Programmed I/O\ " free INIT=JUMPER(5) LOC(1) 0 CHOICE="\ 2nd Party DMA" free INIT=JUMPER(5) LOC(1) 1 FUNCTION="SCSI BIOS " SUBFUNCTION="BIOS Address " COMMENTS="Select the host adapter BIOS base address. This selection must correspond with the Jumper setting of Jumper J9 positions J6 and J4. The BIOS enable jumper on J9 position BE must also be set to reflect whether or not the BIOS is enabled." HELP="Select the base address in system optional ROM memory for the host adapter BIOS. The BIOS will begin at the specified address and is 16KB in length. The BIOS address select jumpers on jumper block J9 positions J6, J4 and BE must be configured to reflect the choices made in this menu. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ C0000h" free MEMORY=16K ADDRESS=0C0000h WRITABLE=NO MEMTYPE=OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=24 INIT=JUMPER(9) LOC(8 7 6) 111 CHOICE="\ C8000h" free MEMORY=16K ADDRESS=0C8000h WRITABLE=NO MEMTYPE=OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=24 INIT=JUMPER(9) LOC(8 7 6) 100 CHOICE="\ CC000h" free MEMORY=16K ADDRESS=0CC000h WRITABLE=NO MEMTYPE=OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=24 INIT=JUMPER(9) LOC(8 7 6) 101 CHOICE="\ D8000h" free MEMORY=16K ADDRESS=0D8000h WRITABLE=NO MEMTYPE=OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=24 INIT=JUMPER(9) LOC(8 7 6) 110 CHOICE= "\ Disable" DISABLE=YES free INIT=JUMPER(9) LOC(8 7 6) 000 SUBFUNCTION="BIOS Boot Operation " COMMENTS="This option allows the user to select whether the AHA-1522 host adapter BIOS performs the boot operation." CHOICE="\ Enable" free INIT=JUMPER(5) LOC(2) 1 CHOICE="\ Disable" free INIT=JUMPER(5) LOC(2) 0 SUBFUNCTION="BIOS Boot Messages " COMMENTS="This option allows the user to select which types of messages are to be displayed when the AHA-1522 performs the boot operation." CHOICE="\ Sign-on and Errors Only" free INIT=JUMPER(5) LOC(4 3) 00 CHOICE="\ Errors Only" free INIT=JUMPER(5) LOC(4 3) 11 CHOICE="\ Sign-on, Boot Progress, and Errors" free INIT=JUMPER(5) LOC(4 3) 10 CHOICE="\ SCSI Device and Jumper Info, Boot Progress, and Errors\ " free INIT=JUMPER(5) LOC(4 3) 01 FUNCTION="SCSI Host " SUBFUNCTION="SCSI Host I/O Address " COMMENTS="Select the host adapter I/O port base address. The I/O port address select jumper at J9 postition AL must correspond to this selection." HELP="Select the base address of the host adapter interface registers in the ISA I/O address space. The jumper that selects the I/O port base address on the host adapter is position AL on Jumper block J9. This jumper must be configured to correspond with the chosen port address. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ Port=340h-35Eh\ " free PORT=340h-35Eh INIT=JUMPER(9) LOC(5) 0 CHOICE="\ Port=140h-15Eh" free PORT=140h-15Eh INIT=JUMPER(9) LOC(5) 1 SUBFUNCTION="SCSI Host Interrupt " COMMENTS="Select the host adapter interrupt channel. This selection must correspond with the Jumper setting of Jumper J9 positions I9, I0, I1, and I2, and Jumper J6 positions IC." HELP="Select which interrupt channel is to be used by the host adapter hardware. The host adapter IRQ select jumpers on both jumper blocks J9 and J6 must be set to correspond with the interrupt channel selected in this menu. On J9, jumper positions I9, I0, I1 and I2 must be configured. Jumper positions IC must configured on J6. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ IRQ=11" free IRQ=11 TRIGGER=EDGE SHARE=NO INIT=JUMPER(9) LOC(1-4) 0100 INIT=JUMPER(6) LOC(4-5) 01 CHOICE="\ IRQ=12" free IRQ=12 TRIGGER=EDGE SHARE=NO INIT=JUMPER(9) LOC(1-4) 1000 INIT=JUMPER(6) LOC(4-5) 11 CHOICE="\ IRQ=10" free IRQ=10 TRIGGER=EDGE SHARE=NO INIT=JUMPER(9) LOC(1-4) 0010 INIT=JUMPER(6) LOC(4-5) 10 CHOICE="\ IRQ= 9" free IRQ=9 TRIGGER=EDGE SHARE=NO INIT=JUMPER(9) LOC(1-4) 0001 INIT=JUMPER(6) LOC(4-5) 00 SUBFUNCTION="SCSI Host DMA Channel " COMMENTS="Select the host adapter DMA channel. Only DMA Channel 0 is supported. This selection must correspond with the Jumper setting of Jumper J8 positions DR, D6, D5 and D0, and J6 positions DC." HELP="Select which DMA channel is to be used by the host adapter hardware. Only DMA Channel 0 is supported. The host adapter DMA select jumpers on both jumper blocks J8 and J6 must be set to correspond with the DMA channel selected in this menu. On J8, jumper positions DR, D6, D5 and D0 must be configured. Jumper positions DC must configured on J6. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ DMA=0" free DMA=0 SHARE=NO INIT=JUMPER(8) LOC(1-8) 00010001 INIT=JUMPER(6) LOC(7 6) 00 GROUP="SCSI Host Configuration" FUNCTION="Host Adapter SCSI ID " COMMENTS="Select the host adapter SCSI ID. This is normally set to ID 7, which has the highest SCSI priority. If you need to change the SCSI ID, the SCSI address select jumpers must be configured to match the SCSI ID desired. These are located at positions SD of J6." HELP="Each device connected to the SCSI bus, including the AHA-1522 must have a unique SCSI ID number. The host adapter is normally configured for ID 7, which has the highest priority on the SCSI bus. This value normally only needs to be changed when more than one host adapter is attached to the same SCSI bus. If this option is changed, the SCSI address selection jumpers at positions SD of jumper block J6 must be configured to select the desired SCSI ID. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ 7" free INIT=JUMPER(6) LOC(1-3) 111 CHOICE="\ 6" free INIT=JUMPER(6) LOC(1-3) 110 CHOICE="\ 5" free INIT=JUMPER(6) LOC(1-3) 101 CHOICE="\ 4" free INIT=JUMPER(6) LOC(1-3) 100 CHOICE="\ 3" free INIT=JUMPER(6) LOC(1-3) 011 CHOICE="\ 2" free INIT=JUMPER(6) LOC(1-3) 010 CHOICE="\ 1" free INIT=JUMPER(6) LOC(1-3) 001 CHOICE="\ 0" free INIT=JUMPER(6) LOC(1-3) 000 FUNCTION="SCSI Bus Parity " COMMENTS="When enabled, the host adapter will check parity on SCSI transfers. The parity disable jumper, position SP of J6, must be installed if this feature is disabled." HELP="The host adapter normally performs parity checking on SCSI transfers. Some devices do not support parity. If you wish to use a device that does not use parity, you must insert the parity disable jumper. The jumper location is position SP on jumper block J6. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ Enable" free INIT=JUMPER(6) LOC(8) 0 CHOICE="\ Disable" free INIT=JUMPER(6) LOC(8) 1 FUNCTION="Allow Target Disconnection " COMMENTS="When enabled, the host adapter will allow targets to disconnect from the SCSI bus. The disconnection jumper, position DN of J5, must be installed if this feature is enabled." HELP="The host adapter can be configured to allow targets to disconnect from the SCSI bus. The disconnection jumper, position DN of J5, must be installed if this feature is enabled. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ Enable" free INIT=JUMPER(5) LOC(6) 1 CHOICE="\ Disable" free INIT=JUMPER(5) LOC(6) 0 FUNCTION="Initiate Synchronous Transfers " COMMENTS="When enabled, the host adapter will initiate synchronous transfer negotiation for SCSI transfers. The synchronous transfer jumper, position SN of J5, must be installed if this feature is enabled." HELP="The host adapter can be configured to initiate synchronous transfer negotiation with SCSI target devices. With devices that support synchronous transfers, but do not initiate synchronous negotiation, it is necessary to enable this option if the faster synchronous transfers are desired. The synchronous transfer jumper, position SN of J5, must be installed if this feature is enabled. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE="\ Disable" free INIT=JUMPER(5) LOC(5) 0 CHOICE="\ Enable" free INIT=JUMPER(5) LOC(5) 1 ENDGROUP GROUP = "AHA-1522 Floppy Controller (Disable if using AHA-1520)" TYPE = "MSD,FPYCTL" FUNCTION = "Floppy Contoller Port " COMMENTS = "Select the floppy controller address, or disable the floppy controller on the AHA-1522. The floppy IRQ and DMA channels are automatically selected when this choice is made. The floppy enable jumper at position FE of J7 must be set to reflect the choices made. The floppy IRQ and DMA jumpers at J7 locations DR, DA, I6 and I0 must also be configured." HELP = "Select the floppy controller address, or disable the floppy controller on the AHA-1522. If the AHA-1522 is the only floppy controller in your system, then the floppy can be enabled. The Floppy enable jumper at position FE of J7 must be set to reflect the choices made. The floppy IRQ and DMA jumpers at J7 locations DR, DA, I6 and I0 must also be configured. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE = "\ Disable" DISABLE = YES LINK INIT = JUMPER(7) LOC(1) 0 CHOICE = "\ Enable" LINK PORT = 3F0H - 3F5H SHARE = NO PORT = 3F6H SHARE = "MSD,DSKCTL" PORT = 3F7H SHARE = NO INIT = JUMPER(7) LOC(1) 1 FUNCTION = "Floppy Contoller Interrupt " CHOICE="\ Disable" free INIT=JUMPER(7) LOC(6 7) 00 CHOICE="\ IRQ=6" LINK IRQ = 6 TRIGGER = EDGE SHARE = NO INIT = JUMPER(7) LOC(6 7) 10 CHOICE="\ IRQ=10" LINK IRQ = 10 TRIGGER = EDGE SHARE = NO INIT = JUMPER(7) LOC(6 7) 01 FUNCTION = "Floppy Contoller DMA Channel " CHOICE="\ Disable" free INIT=JUMPER(7) LOC(2-5) 0000 CHOICE="\ DMA=2" LINK DMA = 2 SHARE = NO INIT = JUMPER(7) LOC(2-5) 1010 CHOICE="\ DMA=3" LINK DMA = 3 SHARE = NO INIT = JUMPER(7) LOC(2-5) 0101 FUNCTION = "Floppy Spindle Speed" COMMENTS = "When enabled, the AHA-1522 floppy controller can support dual speed floppy drives. The dual speed floppy jumper at position DS of J7 must correspond to this selection." HELP = "If you wish to use a floppy drive that supports dual spindle speed operation, the host adapter can be configured to be compatible drive. Normally this feature is disabled, and the floppy drive operates at a single speed. To configure the AHA-1522 for dual speed floppy drives, a jumper is installed at position DS of jumper block J7. Use the configuration utility \"View Jumpers and Switches\" option to determine the correct jumper settings." CHOICE = "\ Single Speed\ " LINK INIT = JUMPER(7) LOC(8) 0 CHOICE = "\ Dual Speed" LINK INIT = JUMPER(7) LOC(8) 1 ENDGROUP