BOARD ; July 07. 1993, Lange, PC E 262 ; Changed switch setting for Receive DMA-Channel = 1 ; Transmit DMA-Channel = 3, SWITCH(5) LOC(6-8) ; from 011 to 010 (Possible DMA Channel contention). ID="SNID663" NAME="SNI PWS-G-DUE-Controller (D663)" MFR="SIEMENS-NIXDORF" CATEGORY="COM" SLOT=ISA8 LENGTH=336 SKIRT=NO AMPERAGE=1200 COMMENTS=" PWS-G-DUE-Controller with REMOTE-POWER-ON electronics. Note: The REMOTE-POWER-ON electronics of the D663 can only be used when the board is installed in one of the SNI machines PWS-M60 or PWS-M70. All switches that control the operation of the REMOTE-POWER-ON-electronics must therefore be set to their default state when the board is installed in a standard EISA machine." SWITCH(1)=8 NAME="SW1-Remote PWR-ON" STYPE=DIP REVERSE=YES FACTORY=LOC(1-8) 10000000 ;INITVAL=LOC(1-8) 10000000 Comments="The settings of SW1 determine the operation of of the REMOTE-POWER-ON electronics. (Datarate, polarity, clock source etc.) Note: The REMOTE-POWER-ON option can not be used in a standard (E)ISA-system." SWITCH(2)=4 NAME="SW2-PWR-ON Event" STYPE=DIP REVERSE=NO FACTORY=LOC(1-4) 0000 ;INITVAL=LOC(1-4) 0000 LABEL = LOC(1-4) "DATA" "M3(RI)" "M5(DCD)" "XX" Comments="Switch SW2 enables one or more REMOTE-POWER-ON events if closed. Note: The REMOTE-POWER-ON option can not be used in a standard (E)ISA-system. Caution: The ON and OFF (OPEN) positions of SW2 are reversed !" SWITCH(3)=4 NAME="SW3-DUE-Module-Power" STYPE=DIP REVERSE=YES FACTORY=LOC(1-4) 0011 ;INITVAL=LOC(1-4) 0011 LABEL = LOC(1-4) "OPEN" "OPEN" "PWR" "PWR" Comments="Switch SW3 determines the source of power for the REMOTE-POWER-ON electronics and the DUE-submodule. Note: All switches must be set to their default setting when the board is installed in a system other than the SNI systems PWS M60 or PWS M70 !" SWITCH(4)=8 NAME="SW4-Intr., DUE-DMA" STYPE=DIP REVERSE=NO FACTORY=LOC(1-8) 00111100 Comments="Switch SW4 is used to select the SAS-interrupt, DUE-interrupt. It is also used in conjunction with SW5 to select the DMA-channel for the DUE receive and transmit channel. Caution: The ON and OFF positions of SW4 are reversed !" SWITCH(5)=8 NAME="SW5-I/O-B., DUE-DMA" STYPE=DIP REVERSE=NO FACTORY=LOC(1-8) 01001010 Comments="Switch SW5 is used to select the I/O-base address, It is also used in conjunction with SW4 to select the DMA-channel for the DUE receive and transmit channel. Caution: The ON and OFF positions of SW5 are reversed ! " FUNCTION="D663 I/O-Addresses" TYPE="COM,HDLC" CHOICE="I/O-Base-Address = 220h" LINK PORT=220h-22Fh INIT=SWITCH(5) LOC(4-5) 11 CHOICE="I/O-Base-Address = 260h" LINK PORT=260h-26Fh INIT=SWITCH(5) LOC(4-5) 01 CHOICE="I/O-Base-Address = 2A0h" LINK PORT=2A0h-2AFh INIT=SWITCH(5) LOC(4-5) 10 CHOICE="I/O-Base-Address = 2E0h" LINK PORT=2E0h-2EFh INIT=SWITCH(5) LOC(4-5) 00 ; 25.05.93. (Mertes, E222) Sharing of ISA-Interrupt in order to use ; D663/IHSS in PCE-4T/SINIX-Z with same Interrupt for SAS/DUE ; (only Hardware). SAS is not used by SINIX-Z! HW-Interrupt-Disable ; for SAS is not possible! Changed Default to IRQ 11. FUNCTION="D663 SAS-Interrupt" TYPE="COM,HDLC" CHOICE="IRQ 11" LINK IRQ = 11 SHARE="SNID663" INIT=SWITCH(4) LOC(5-6) 01 CHOICE="IRQ 10" LINK IRQ = 10 SHARE="SNID663" INIT=SWITCH(4) LOC(5-6) 11 CHOICE="IRQ 12" LINK IRQ = 12 SHARE="SNID663" INIT=SWITCH(4) LOC(5-6) 10 CHOICE="IRQ 15" LINK IRQ = 15 SHARE="SNID663" INIT=SWITCH(4) LOC(5-6) 00 FUNCTION="D663 DUE-Interrupt" TYPE="COM,HDLC" CHOICE="IRQ 11" LINK IRQ = 11 SHARE="SNID663" INIT=SWITCH(4) LOC(7-8) 01 CHOICE="IRQ 10" LINK IRQ = 10 SHARE="SNID663" INIT=SWITCH(4) LOC(7-8) 11 CHOICE="IRQ 12" LINK IRQ = 12 SHARE="SNID663" INIT=SWITCH(4) LOC(7-8) 10 CHOICE="IRQ 15" LINK IRQ = 15 SHARE="SNID663" INIT=SWITCH(4) LOC(7-8) 00 FUNCTION="D663 DUE-DMA-Channel" TYPE="COM,HDLC" CHOICE="No DMA" LINK INIT=SWITCH(5) LOC(1-3) 000 INIT=SWITCH(5) LOC(6-8) 010 INIT=SWITCH(4) LOC(2-4) 000 CHOICE="Receive: DMA 0, Transmit: DMA 1" LINK DMA=0 DMA=1 INIT=SWITCH(5) LOC(1-3) 010 INIT=SWITCH(5) LOC(6-8) 010 INIT=SWITCH(4) LOC(2-4) 011 CHOICE="Receive: DMA 1, Transmit: DMA 3" LINK DMA=1 DMA=3 INIT=SWITCH(5) LOC(1-3) 010 INIT=SWITCH(5) LOC(6-8) 010 INIT=SWITCH(4) LOC(2-4) 110 CHOICE="Receive: DMA 1, Transmit: DMA 1" LINK DMA=1 INIT=SWITCH(5) LOC(1-3) 010 INIT=SWITCH(5) LOC(6-8) 010 INIT=SWITCH(4) LOC(2-4) 001 CHOICE="Receive: DMA 0, Transmit: DMA 0" LINK DMA=0 INIT=SWITCH(5) LOC(1-3) 001 INIT=SWITCH(5) LOC(6-8) 001 INIT=SWITCH(4) LOC(2-4) 001 CHOICE="Receive: DMA 0, Transmit: DMA 3" LINK DMA=0 DMA=3 INIT=SWITCH(5) LOC(1-3) 001 INIT=SWITCH(5) LOC(6-8) 001 INIT=SWITCH(4) LOC(2-4) 110 CHOICE="Receive: DMA 3, Transmit: DMA 3" LINK DMA=3 INIT=SWITCH(5) LOC(1-3) 100 INIT=SWITCH(5) LOC(6-8) 100 INIT=SWITCH(4) LOC(2-4) 001 FUNCTION="D663 SASWAIT-NMI" CHOICE="Disable NMI on SASWAIT Fault" LINK INIT=SWITCH(4) LOC(1) 0 CHOICE="Enable NMI on SASWAIT Fault" LINK INIT=SWITCH(4) LOC(1) 1 FUNCTION="D663 Remote POWER ON" SUBFUNCTION="Remote POWER ON events" CHOICE="Disable REMOTE POWER ON" LINK INIT=SWITCH(2) LOC(1-4) 0000 CHOICE="POWER ON when M3 (RI) active" LINK INIT=SWITCH(2) LOC(2) 1 CHOICE="POWER ON when M5 (DCD) active" LINK INIT=SWITCH(2) LOC(3) 1 CHOICE="POWER ON upon receipt of datapattern" LINK INIT=SWITCH(2) LOC(1) 1 SUBFUNCTION="Mode of Operation" CHOICE="NRZ Data" LINK INIT=SWITCH(1) LOC(1) 1 CHOICE="NRZI Data" LINK INIT=SWITCH(1) LOC(1) 0 SUBFUNCTION="Clock Source" CHOICE="Internal" LINK INIT=SWITCH(1) LOC(2) 0 CHOICE="External" LINK INIT=SWITCH(1) LOC(2) 1 SUBFUNCTION="Data Rate" CHOICE="1200 bit/sec" LINK INIT=SWITCH(1) LOC(3-5) 011 CHOICE="2400 bit/sec" LINK INIT=SWITCH(1) LOC(3-5) 001 CHOICE="4800 bit/sec" LINK INIT=SWITCH(1) LOC(3-5) 010 CHOICE="9600 bit/sec" LINK INIT=SWITCH(1) LOC(3-5) 000 CHOICE="19200 bit/sec" LINK INIT=SWITCH(1) LOC(3-5) 111 SUBFUNCTION="Data Polarity" CHOICE="Normal" LINK INIT=SWITCH(1) LOC(6) 0 CHOICE="Inverted" LINK INIT=SWITCH(1) LOC(6) 1 SUBFUNCTION="Data Pattern" CHOICE="64 bytes 0CCh" LINK INIT=SWITCH(1) LOC(7) 1 CHOICE="28 bytes 'special'" LINK INIT=SWITCH(1) LOC(7) 0 SUBFUNCTION="Trigger on" CHOICE="Negative Slope" LINK INIT=SWITCH(1) LOC(8) 1 CHOICE="Positive Slope" LINK INIT=SWITCH(1) LOC(8) 0 FUNCTION="DUE Power Source" CHOICE="(E)ISA-BUS" LINK INIT=SWITCH(3) LOC(1-4) 0011 CHOICE="Standby PWR-Supply" LINK INIT=SWITCH(3) LOC(1-4) 0000