BOARD ID = "NIC1400" NAME = "AT-MIO-64F-5 Multi-function Board" MFR = "NATIONAL INSTR CORP" CATEGORY = "OTH" SLOT = ISA16 READID = NO COMMENTS = "The AT-MIO-64F-5 is a high-perfomance multi-function analog, digital and timing input/output board." HELP = "The AT-MIO-64F-5 contains a 12-bit A/D converter with up to 64 analog inputs, two 12-bit D/A converters with voltage outputs, eight lines of TTL compatible digital input and output, and three 16-bit counter/timer channels for timing input and output." SWITCH(1) = 5 NAME = "Base I/O Address" STYPE = DIP VERTICAL = NO REVERSE = YES LABEL = LOC(1-5) "A9" "A8" "A7" "A6" "A5" FACTORY = LOC(1-5) 10001 COMMENTS = "The base I/O address is determined by the settings of the board dip switches. The factory setting is for base address 0220h." FUNCTION = "AT-MIO-64F-5 Base I/O Address" COMMENTS = "The base I/O address selected through this resource." HELP = "The base I/O address entered here must match the board dip switch setting for the base address. See the user's manual of the board for more information." CHOICE = "Base I/O address Resource" SUBCHOICE FREE PORT = 220h-3FFh STEP = 020h SHARE = NO INIT = SWITCH(1) LOC(1-5) 10001 | 10010 | 10011 | 10100 | 10101 | 10110 | 10111 | 11000 | 11001 | 11010 | 11011 | 11100 | 11101 | 11110 | 11111 SUBCHOICE FREE PORT = 000h-220h STEP = 020h SHARE = NO INIT = SWITCH(1) LOC(1-5) 00000 | 00001 | 00010 | 00011 | 00100 | 00101 | 00110 | 00111 | 01000 | 01001 | 01010 | 01011 | 01100 | 01101 | 01110 | 01111 | 10000 FUNCTION = "AT-MIO-64F-5 DMA Channels" COMMENTS = "The DMA channel to be used is selected through this function. \n\nIf you select the Disabled option, the driver will not perform DMA transfers through the board. However, if you select the Disabled option, you must also set the Data Acquisition mode to Programmed Input/Output for the driver to perform Data Acquisition functions on the board." ;SHARE statement in the choices is omitted as default is NO CHOICE = "DMA A and B enabled" COMBINE DMA = 6 | 5 | 3 | 2 | 1 | 0 | 7 DMA = 7 | 6 | 5 | 3 | 2 | 1 | 0 CHOICE = "DMA A enabled & DMA B disabled" FREE DMA = 6 | 5 | 3 | 2 | 1 | 0 | 7 CHOICE = "DMA A disabled & DMA B enabled" FREE DMA = 7 | 6 | 5 | 3 | 2 | 1 | 0 CHOICE = "DMA A & B disabled" DISABLE = YES FUNCTION = "AT-MIO-64F-5 Interrupt Request Level" COMMENTS = "The interrupt level is selected through this function." ;SHARE statement in the choices is omitted as default is NO ;TRIGGER statement in the choices is omitted as default is EDGE ; The default values assigned for SHARE and TRIGGER are being ignored. CHOICE = "10" FREE IRQ = 10 CHOICE = "11" FREE IRQ = 11 CHOICE = "12" FREE IRQ = 12 CHOICE = "15" FREE IRQ = 15 CHOICE = "3" FREE IRQ = 3 CHOICE = "4" FREE IRQ = 4 CHOICE = "5" FREE IRQ = 5 CHOICE = "7" FREE IRQ = 7 CHOICE = "Disable" DISABLE = YES