BOARD ID = "ICU0950" NAME = "Acculogic sIDE-3/plus" MFR = "Acculogic" CATEGORY = "MSD" SLOT = ISA16 VERSION = 3.0 JUMPER(1) = 1 NAME = "IRQ normal" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "J1" FACTORY = LOC(1) 1 JUMPER(2) = 1 NAME = "IRQ delay" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP2" FACTORY = LOC(1) 0 JUMPER(3) = 1 NAME = "Floppy drive port address" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP6" FACTORY = LOC(1) 0 JUMPER(4) = 1 NAME = "Hard Drive port address" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP7" FACTORY = LOC(1) 0 JUMPER(5) = 1 NAME = "Floppy drive speed" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP8" FACTORY = LOC(1) 0 JUMPER(6) = 1 NAME = "Hard Drive port address" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP9" FACTORY = LOC(1) 0 JUMPER(7) = 1 NAME = "I/O Channel Ready signal" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP10" FACTORY = LOC(1) 0 JUMPER(8) = 1 NAME = "BIOS Enable" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP11" FACTORY = LOC(1) 0 JUMPER(9) = 1 NAME = "Drive A: supports 2.88MB" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP14" FACTORY = LOC(1) 0 JUMPER(10) = 1 NAME = "Drive B: supports 2.88MB" JTYPE = PAIRED VERTICAL = YES LABEL = LOC(1) "JP14" FACTORY = LOC(1) 0 FUNCTION = "IDE Controller" TYPE = "IDE" SUBFUNCTION = "BIOS Address" CHOICE = "Enable" FREE MEMORY = 16K ;CC000-C8000=4000H ADDRESS = 0C8000H |0CC000H|0D8000H |0DC000H WRITABLE = NO MEMTYPE = OTH SHARE = NO INIT = JUMPER(7) LOC(1) 0 CHOICE = "Disabled" DISABLE = YES FREE INIT = JUMPER(7) LOC(1) 1 SUBFUNCTION = "IRQ" CHOICE = "IRQ Normal" FREE INIT = JUMPER(1) LOC(1) 0 INIT = JUMPER(2) LOC(1) 1 CHOICE = "IRQ Delayed" FREE INIT = JUMPER(1) LOC(1) 1 INIT = JUMPER(2) LOC(1) 0 SUBFUNCTION = "Hard Drive" CHOICE = "1F0-1F7" FREE PORT = 01F0H-01F7H FREE IRQ = 14 CHOICE = "170-177" FREE PORT = 0170H-0177H FREE IRQ = 14 CHOICE = "Disabled" DISABLE = YES FUNCTION = "Floppy Drive" TYPE = "FDC" SUBFUNCTION = "Ports" CHOICE = "3F0-3F7" FREE PORT = 03F0H-03F7H FREE IRQ = 6 FREE DMA = 2 CHOICE = "370-377" FREE PORT = 0370H-0377H FREE IRQ = 6 FREE DMA = 2 CHOICE = "Disabled" DISABLE = YES SUBFUNCTION = "Floppy Drives Speed" CHOICE = "Single" FREE INIT = JUMPER(5) LOC(1) 0 CHOICE = "Dual" FREE INIT = JUMPER(5) LOC(1) 1 SUBFUNCTION = "2.88 MB drives" CHOICE = "Not Supported on A:" FREE INIT = JUMPER(8) LOC(1) 0 CHOICE = "Supported on A:" FREE INIT = JUMPER(8) LOC(1) 1 SUBFUNCTION = "2.88 MB drives" CHOICE = "Not Supported on B:" FREE INIT = JUMPER(9) LOC(1) 0 CHOICE = "Supported on B:" FREE INIT = JUMPER(9) LOC(1) 1