;------------------------------------------------------ ; file name = !DTC1101.CFG, last changed 3-16-92 ;------------------------------------------------------ BOARD ID = "DTC1101" NAME = "DTC2290 EISA IDE Controller" MFR = "Data Technology" CATEGORY = "MSD" SLOT=EISA LENGTH=195 AMPERAGE = 1500 READID = NO ; No id support by this dump board IOCHECK = INVALID DISABLE = UNSUPPORTED COMMENTS = " DTC2290 is a high performance EISA IDE controller.\n The features of this board are:\n - Fully EISA Compatible\n - Supports multiple sectors transfer\n - Supports 32 bits Data Transfers\n - Supports drive over 512 MB\n - Support 8Mbytes/sec Data Transfer Rate\n - Support 2 IDE ports with up to 4 IDE Drives\n - Support up to 4 2.88M Floppy Disk Drives" JUMPER(1)=4 NAME="JUMPER W1 THRU W4" JTYPE=PAIRED VERTICAL=YES REVERSE=NO LABEL=LOC(4 3 2 1) "W4-DTC/IBM""W3-BIOSEN""W2-ALTMEM1""W1-ALTMEM2" INITVAL=LOC(4 3 2 1) xxxx FACTORY=LOC(4 3 2 1) 0100 HELP=" The DTC2x90 on-board BIOS is\n enabled when W3 is installed.\n The address where the BIOS is located is defined by W1 and W2;\n such that when\n W1 - OPENED and W2 - OPENED then\n BIOS range is C8000 to CBFFF\n W1 - OPENED and W2 - CLOSED then\n BIOS range is D0000 to D3FFF\n W1 - CLOSED and W2 - CLOSED then\n BIOS range is D4000 to D7FFF\n W1 - CLOSED and W2 - CLOSED then\n BIOS range is D7FFF to DBFFF.\n OPEN W4 if a twisted ribbon\n cable is used. CLOSE W4 if\n a flat ribbon cable is used." JUMPER(2)=4 NAME="JUMPER W5 THRU W8" JTYPE=PAIRED VERTICAL=NO REVERSE=NO LABEL=LOC(4 3 2 1) "W8 DRV3""W7 DRV2""W6 DRV1""W5 DRV0" INITVAL=LOC(4 3 2 1) xxxx FACTORY=LOC(4 3 2 1) 0000 HELP=" Jumper W5 through W8 is used by\n the DTC2x90 to translate drive\n parameters for each attached\n drive as though they have\n 64 heads with 63 sectors/track.\n W5 CLOSED maps Port 1 Master.\n W6 CLOSED maps Port 1 SLAVE.\n W7 CLOSED maps Port 2 Master.\n W8 CLOSED maps Port 2 SLAVE." ; Use to set up port speed IOPORT(1) = 0ZC74h INITVAL = LOC(7-0) xxxxxxxx FUNCTION = "IDE Subsystem" TYPE = "MSD" ; Choices that have been commented out have not ; been tested but reflect manufacturer's specification ; for maximum host data transfer. SUBFUNCTION = "SET DATA TRANSFER RATE FOR PORT 1" COMMENTS = "This setting is used to maximize the data\n transfer that an attached drive can sustain." HELP = " This setting is used to maximize\n the data transfer that the drive\n can sustain.\n ----------- CAUTION ------------\n If there are two drives attached\n to one port, you must choose the\n slower drive's speed for that port." CHOICE = "MODE 0 3.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "MODE 1 5.1MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1110 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "MODE 2 8.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1010 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "BRAND BT9170A/BT9220A 7.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1001 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "CONNER CP2024 3.7MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 0010 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP2034/CP2044/CP2064 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1100 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP2084 6.2MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1000 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP344 4.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 0011 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "CONNER CP3000/CP3024/CP3044 4.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1100 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "CONNER CP3104/CP3114/CP3184 3.7MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 0010 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3204F 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1100 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3304/CP3504 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1010 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3364 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1010 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3544 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1010 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP30064/CP30084 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1100 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "CONNER CP30104 4.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1100 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "CONNER CP30084E/CP30174E 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1111 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "CONNER CP30204 8.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1010 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "FUJITSU M2611T/M2612T/M2613T 7.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1001 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "FUJITSU M2614ET 3.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "FUJITSU M2622T/M2623T/M2624T 7.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1001 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "HP C2233/C2234/C2235 6.2MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "KALOK KL3100 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1100 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "MAXTOR LXT7120A 3.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "MAXTOR LXT213A 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "MAXTOR LXT340A 8.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1010 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "QUANTUM LPS52AT 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "QUANTUM LPS120AT/LPS240AT 4.6MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1101 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "SEAGATE ST125A/ST138A/ST157A 4.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 0011 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST351A 4.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1101 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST1057A/ST1102A/ST1144A 4.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 0011 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST1090A/ST1126A/ST1162A 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1111 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST1186A/ST1201A/ST1239A 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1111 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "SEAGATE ST1400A/ST1401A/ST1480A 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE ; CHOICE = "SEAGATE ST3096A/ST3120A/ST3144A 4.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(3-0) 1101 ; PORT=1F0h-1F7h ; IRQ=14 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "WESTERN DIGITAL WDAC2120 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "WESTERN DIGITAL WDAP4200 4.6MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1101 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED K 8.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1010 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED J 7.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1001 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED I 6.2MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED H 5.6MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1111 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED G 5.1MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1110 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED F 4.6MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1101 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED E 4.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1100 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED D 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED C 3.7MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0010 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED B 3.5MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0001 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED A 3.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0000 PORT=1F0h-1F7h IRQ=14 SHARE=NO TRIGGER=EDGE CHOICE = "DISABLED" LINK INIT = IOPORT(1) LOC(3-0) 0000 SUBFUNCTION = "SET DATA TRANSFER RATE FOR PORT 2" COMMENTS = "This setting is used to maximize the data\n transfer that an attached drive can sustain.\n" HELP=" This setting is used to maximize\n the data transfer that the drive\n can sustain.\n ----------- CAUTION ------------\n If there are two drives attached\n to one port, you must choose the\n slower drive's speed for that port." CHOICE = "MODE 0 3.3MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "MODE 1 5.1MB/S" LINK INIT = IOPORT(1) LOC(3-0) 1110 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "MODE 2 8.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1010 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "BRAND BT9170A/BT9220A 7.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1001 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "CONNER CP3000/CP3024/CP3044 4.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1100 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE ; CHOICE = "CONNER CP3104/CP3114/CP3184 3.7MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 0010 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3204F 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1100 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3304/CP3504 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1010 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3364 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1010 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP3544 8.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1010 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "CONNER CP30064/CP30084 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1100 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "CONNER CP30104 4.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1100 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE ; CHOICE = "CONNER CP30084E/CP30174E 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1111 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "CONNER CP30204 8.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1010 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "FUJITSU M2614ET 3.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "FUJITSU M2622T/M2623T/M2624T 7.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1001 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "HP C2233/2234/2235 6.2MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE ; CHOICE = "KALOK KL3100 4.3MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1100 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "MAXTOR LXT7120A 3.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "MAXTOR LXT213A 4.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0011 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "MAXTOR LXT340A 8.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1010 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "QUANTUM LPS52AT 4.0MB/S" LINK INIT = IOPORT(1) LOC(3-0) 0011 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "QUANTUM LPS120AT/LPS240AT 4.6MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1101 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE ; CHOICE = "SEAGATE ST1057A/ST1102A/ST1144A 4.0MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 0011 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST1090A/ST1126A/ST1162A 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1111 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE ; CHOICE = "SEAGATE ST1186A/ST1201A/ST1239A 5.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1111 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "SEAGATE ST1400A/ST1401A/ST1480A 4.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0011 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE ; CHOICE = "SEAGATE ST3096A/ST3120A/ST3144A 4.6MB/S" ; LINK ; INIT = IOPORT(1) LOC(7-4) 1101 ; PORT=170h-177h ; IRQ=15 ; SHARE=NO ; TRIGGER=EDGE CHOICE = "WESTERN DIGITAL WDAC2120 4.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0011 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "WESTERN DIGITAL WDAP4200 4.6MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1101 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED K 8.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1010 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED J 7.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1001 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED I 6.2MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED H 5.6MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1111 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED G 5.1MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1110 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED F 4.6MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1101 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED E 4.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 1100 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED D 4.0MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0011 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED C 3.7MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0010 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED B 3.5MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0001 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "SPEED A 3.3MB/S" LINK INIT = IOPORT(1) LOC(7-4) 0000 PORT=170h-177h IRQ=15 SHARE=NO TRIGGER=EDGE CHOICE = "DISABLED" LINK INIT = IOPORT(1) LOC(7-4) 0000 FUNCTION="DTC2290 BIOS Memory W3-CLOSED" TYPE="MEM" HELP=" Use this option only to verify\n resource conflicts. Actual address\n selection is performed with on-\n board jumpers W1, W2 and W3 only." CHOICE="C8000-CBFFF W1-OPENED W2-OPENED" FREE MEMORY=14K ADDRESS=0C8000h WRITABLE=NO MEMTYPE=SYS CACHE=YES SHARE=NO SIZE=BYTE DECODE=20 MEMORY=2K ADDRESS=0CB800h WRITABLE=YES MEMTYPE=SYS CACHE=NO SHARE=NO SIZE=BYTE DECODE=20 INIT=JUMPER(1) LOC(3 2 1) 100 CHOICE="D0000-D3FFF W1-OPENED W2-CLOSED" FREE MEMORY=14K ADDRESS=0D0000h WRITABLE=NO MEMTYPE=SYS CACHE=YES SHARE=NO SIZE=BYTE DECODE=20 MEMORY=2K ADDRESS=0D3800h WRITABLE=YES MEMTYPE=SYS CACHE=NO SHARE=NO SIZE=BYTE DECODE=20 INIT=JUMPER(1)LOC(3 2 1) 101 CHOICE="D4000-D7FFF W1-CLOSED W2-CLOSED" FREE MEMORY=14K ADDRESS=0D4000h WRITABLE=NO MEMTYPE=SYS CACHE=YES SHARE=NO SIZE=BYTE DECODE=20 MEMORY=2K ADDRESS=0D7800h WRITABLE=YES MEMTYPE=SYS CACHE=NO SHARE=NO SIZE=BYTE DECODE=20 INIT=JUMPER(1) LOC(3 2 1) 111 CHOICE="D8000-DBFFF W1-CLOSED W2-OPENED" FREE MEMORY=14K ADDRESS=0D8000h WRITABLE=NO MEMTYPE=SYS SHARE=NO SIZE=BYTE DECODE=20 MEMORY=2K ADDRESS=0DB800h WRITABLE=YES MEMTYPE=SYS SHARE=NO SIZE=BYTE DECODE=20 INIT=JUMPER(1) LOC(3 2 1) 110 FUNCTION="DTC2290 Floppy Controller" TYPE="MSD" HELP=" Use this option only to verify\n resource conflicts. The floppy\n controller is automatically\n enabled when a drive is\n attached to the J1 connector." CHOICE="Floppy Enabled" LINK PORT=3F0h-3F5h PORT=3F6h-3F7h IRQ=6 CHOICE="Floppy Disabled" SOFTWARE(1)="DTC2290.SYS -\n is a DOS driver to get better\n drive performance. Place the\n following command line in\n CONFIG.SYS.\n \n device=DTC2290.sys" SOFTWARE(2)="DTCDISK.SYS -\n is a DOS driver to access the\n SECONDARY Port 2. Place the\n following command line in\n CONFIG.SYS after DTC2290.SYS.\n \n device=dtcdisk.sys" FUNCTION="DTC2290 Floppy Cable Selection (W4)" TYPE="MSD" HELP=" Use this option only to verify\n jumper settings. Actual\n operation is selected by jumper\n installation only." SUBFUNCTION="DTC2290 Floppy Cable Selection" CHOICE="Twisted Ribbon Cable Option W4-OPENED" LINK INIT=JUMPER(1) LOC(4) 0 CHOICE="Flat Ribbon Cable Option W4-CLOSED" LINK INIT=JUMPER(1) LOC(4) 1 FUNCTION="DTC2290 64-HEAD Mapping" TYPE="MSD" HELP=" Use this option only to verify\n jumper settings. Actual\n operation is selected by jumper\n installation only." SUBFUNCTION="PORT 1 MASTER Drive (W5)" CHOICE="Disable 64-HEAD Mapping W5-OPENED" LINK INIT=JUMPER(2) LOC(1) 0 CHOICE="Enable 64-HEAD Mapping W5-CLOSED" LINK INIT=JUMPER(2) LOC(1) 1 SUBFUNCTION="PORT 1 SLAVE Drive (W6)" CHOICE="Disable 64-HEAD Mapping W6-OPENED" LINK INIT=JUMPER(2) LOC(2) 0 CHOICE="Enable 64-HEAD Mapping W6-CLOSED" LINK INIT=JUMPER(2) LOC(2) 1 SUBFUNCTION="PORT 2 MASTER Drive (W7)" CHOICE="Disable 64-HEAD Mapping W7-OPENED" LINK INIT=JUMPER(2) LOC(3) 0 CHOICE="Enable 64-HEAD Mapping W7-CLOSED" LINK INIT=JUMPER(2) LOC(3) 1 SUBFUNCTION="PORT 2 SLAVE Drive (W8)" CHOICE="Disable 64-HEAD Mapping W8-OPENED" LINK INIT=JUMPER(2) LOC(4) 0 CHOICE="Enable 64-HEAD Mapping W8-CLOSED" LINK INIT=JUMPER(2) LOC(4) 1