; ; OmniTel 2400 Baud Internal Modem ; ISA CFG Version 1.00 ; BOARD ID = "DELFB00" NAME = "OmniTel 2400 Baud Internal Modem" MFR = "OMNITEL" CATEGORY = "COM" SLOT = ISA8 LENGTH = 127 DISABLE = UNSUPPORTED SWITCH(1) = 6 STYPE = DIP NAME = "SW1" COMMENTS = "Switch SW1 (on the back bracket of the modem) contains six DIP switches. See the switch positions listed below.\n \n OFF = UP = 0, ON = DOWN = 1\n \n Switch Positions: \n 1,2 - 11 = COM1 \n 10 = COM2 \n 01 = COM3 \n 00 = COM4 \n 3 - 1 = DTR forced on \n 0 = DTR software programmable \n 4 - 1 = CD forced on \n 0 = CD normal \n 5,6 - 0 = Reserved \n \n Note: The actual position of each DIP switch is opposite \n to that which is shown. 0=OFF=Switch is up (to the left), \n 1=ON=Switch is down (to the right)." FACTORY = LOC(1-6) 100000 VERTICAL = YES REVERSE = NO INITVAL = LOC(5-6) 00 JUMPER(1) = 2 JTYPE = INLINE NAME = "J5" COMMENTS = "Jumper J5 defines how the modem generates its clear to send (CTS) control signal (factory-set so CTS is turned OFF when the communications software turns ON the request to send (RTS) signal). Reset J5 only if CTS is required to be ON when the carrier detect (CD) signal is ON. See your modem and software manuals if you are in doubt about setting J5.\n \n Jumper Positions: \n A = CTS follows RTS \n B = CTS follows CD" VERTICAL = NO REVERSE = NO LABEL= LOC(3^2 2^1) "B" "A" FACTORY = LOC(3^2 2^1) 01 INITVAL = LOC(3^2 2^1) 01 JUMPER(2) = 2 JTYPE = INLINE NAME = "J6" COMMENTS = "If the modem is configured for the COM3 serial port address, jumper J6 is used to select whether the modem generates interrupt request IRQ4 or IRQ5. See your modem and software manuals if you are in doubt about setting J6.\n \n Jumper Positions: \n A = COM3 generates IRQ4 \n B = COM3 generates IRQ5" VERTICAL = NO LABEL=LOC(1^2 2^3) "A" "B" REVERSE = YES FACTORY = LOC(1^2 2^3) 10 JUMPER(3) = 2 JTYPE = INLINE NAME = "J7" COMMENTS = "If the modem is configured for the COM4 serial port address, jumper J7 is used to select whether the modem generates interrupt request IRQ3 or IRQ2. See your modem and software manuals if you are in doubt about setting J7.\n \n Jumper Positions: \n A = COM4 generates IRQ3 \n B = COM4 generates IRQ2" VERTICAL = NO LABEL=LOC(1^2 2^3) "A" "B" REVERSE = YES FACTORY = LOC(1^2 2^3) 10 FUNCTION = "Internal Modem as COM1-COM4" COMMENTS = "This option allows you to choose the serial port address (COM1 through COM4) at which the modem transmits and receives data. Each serial device in your system must have a unique COM port address. The Encore 2400HB is factory-set to use COM2 with switch SW1 (DIP switches 1 and 2). However, you can select COM1, COM3, or COM4 if needed to avoid COM port conflicts with other serial devices or if your communications software requires a different COM port. Be sure switch SW1 (DIP switches 1 and 2) are set to the same COM port you select with this option." TYPE = "COM,ASY" CHOICE = "COM1" SUBTYPE = "COM1" LINK IRQ = 4 SHARE="COM,ASY" PORT = 3F8h-3FFh INIT = SWITCH(1) LOC(1-2) 11 INIT = JUMPER(3) LOC(1^2 2^3) 10 INIT = JUMPER(2) LOC(1^2 2^3) 10 CHOICE = "COM2" SUBTYPE = "COM2" LINK IRQ = 3 SHARE="COM,ASY" PORT = 2F8h-2FFh INIT = SWITCH(1) LOC(1-2) 10 INIT = JUMPER(3) LOC(1^2 2^3) 10 INIT = JUMPER(2) LOC(1^2 2^3) 10 CHOICE = "COM3" SUBTYPE = "COM3" LINK IRQ = 4 | 5 SHARE="COM,ASY" INIT = JUMPER(2) LOC(1^2 2^3) 10 | 01 link PORT = 3E8h-3EFh INIT = SWITCH(1) LOC(1-2) 01 INIT = JUMPER(3) LOC(1^2 2^3) 10 CHOICE = "COM4" SUBTYPE = "COM4" LINK IRQ = 3 | 2 SHARE="COM,ASY" INIT = JUMPER(3) LOC(1^2 2^3) 10 | 01 link PORT = 2E8h-2EFh INIT = SWITCH(1) LOC(1-2) 00 INIT = JUMPER(2) LOC(1^2 2^3) 10