; ; HPFP Configuration File V1.0 ; BOARD ID = "ACS0501" NAME = "Altos High-Performance File Processor" MFR = "Altos" CATEGORY = "MSD" SLOT = EISA LENGTH = 330 AMPERAGE = 6500 SKIRT = NO READID = YES BUSMASTER = 50 IOCHECK = INVALID DISABLE = SUPPORTED COMMENTS = "The HPFP is a single ported SCSI controller that may be turned into a dual ported SCSI controller with an optional daughter card." ; ; I/O Control Ports ; IOPORT(1) = 0zC8CH SIZE = DWORD INITVAL = 00000000000011xxxxxx000000001111b IOPORT(2) = 0z4D1H SIZE = BYTE INITVAL = xxxxxxxx ; ; Jumpers ; JUMPER(1) = 1 NAME = "JX1" JTYPE = PAIRED VERTICAL = NO REVERSE = NO FACTORY = LOC (1) 1 COMMENTS = "If this jumper is installed, the board will generate level triggered interrupts" JUMPER(2) = 1 NAME = "JA1" JTYPE = PAIRED VERTICAL = NO REVERSE = NO FACTORY = LOC (1) 1 COMMENTS = "Installing this jumper supplies terminator power to the SCSI bus." JUMPER(3) = 11 NAME = "JAX1" JTYPE = PAIRED VERTICAL = NO REVERSE = NO INITVAL = LOC(1 2 3 4 5 6 7 8)11000000 FACTORY = LOC(1 2 3 4 5 6 7 8 9 10 11)11000000000 COMMENTS = "JAX1 Jumpers set the SCSI ID for channel 0 plus whether or not the SCSI bus is reset on power up or board reset and whether or not the 4810 extended diagnostic is run on power up. With JAX1 pins 1-2 installed, SCSI bus reset at power on is not done and with JAX1 pins 3-4 installed, extended diagnostic is not performed." JUMPER(4) = 1 NAME = "JAX2" JTYPE = PAIRED VERTICAL = NO REVERSE = NO INITVAL = LOC(1) 1 FACTORY = LOC(1) 1 COMMENTS = "This jumper is used to isolate 36 MHZ OSC from logic on the board. It is to be removed only for manufacturing board test." JUMPER(5) = 1 NAME = "JA2" JTYPE = PAIRED VERTICAL = YES REVERSE = NO INITVAL = LOC(1) 1 FACTORY = LOC(1) 1 COMMENTS = "This jumper is used to isolate 24 MHZ processor clock from logic on the board. It is to be removed only for manufacturing board test." JUMPER(6) = 1 NAME = "JA4" JTYPE = PAIRED VERTICAL = YES REVERSE = NO INITVAL = LOC(1) 0 FACTORY = LOC(1) 0 COMMENTS = "The setting on this jumper should not be changed." JUMPER(7) = 1 NAME = "JA5" JTYPE = PAIRED VERTICAL = YES REVERSE = NO INITVAL = LOC(1) 1 FACTORY = LOC(1) 1 COMMENTS = "This jumper is used to isolate 24 MHZ SCSI clock from Logic on the board. It is to be removed only for manufacturing board test." JUMPER(8) = 2 NAME = "JA6" JTYPE = INLINE VERTICAL = NO REVERSE = NO INITVAL = LOC(1^2 2^3) 01 FACTORY = LOC(1^2 2^3) 01 COMMENTS = "256k EPROMS are enabled by installing the jumper on 2^3. For 512k EPROMS the jumper must be installed on 1^2." JUMPER(9) = 1 NAME = "JA1 ON DAUGHTER CARD" JTYPE = PAIRED VERTICAL = YES REVERSE = YES FACTORY = LOC(1) 1 COMMENTS = "JA1-3 set the SCSI ID for channel 1" JUMPER(10) = 1 NAME = "JA2 ON DAUGHTER CARD" JTYPE = PAIRED VERTICAL = YES REVERSE = YES FACTORY = LOC(1) 1 COMMENTS = "JA1-3 set the SCSI ID for channel 1" JUMPER(11) = 1 NAME = "JA3 ON DAUGHTER CARD" JTYPE = PAIRED VERTICAL = YES REVERSE = YES FACTORY = LOC(1) 1 COMMENTS = "JA1-3 set the SCSI ID for channel 1" JUMPER(12) = 1 NAME = "JA4 ON DAUGHTER CARD" JTYPE = PAIRED VERTICAL = YES REVERSE = YES FACTORY = LOC(1) 1 COMMENTS = "Installing this jumper supplies terminator power to the SCSI bus." FUNCTION = "HPFP SCSI Controller" TYPE = "MSD,HPFP" SUBFUNCTION = "RESOURCE CONFIGURATION" COMMENTS = "It is through this dual ported memory that all commands and status are passed between the HPFP and the host system." CHOICE = "CONFIGURE MEMORY, PORTS, INTERRUPTS" LINK MEMORY = 4k ADDRESS = 0C8000h-0E8000h STEP = 4K MEMTYPE = OTH WRITABLE = YES SIZE = DWORD CACHE = NO INIT = IOPORT(1) LOC(17-12) 001000-101000 FREE PORT = 0z4D1h SIZE = BYTE INIT = IOPORT(2) 00001000 SUBCHOICE FREE IRQ = 14|15|7|11|5|10|12|3|4|6 SHARE = "msd" TRIGGER = LEVEL INIT = JUMPER(1) LOC(1) 1 SUBCHOICE FREE IRQ = 14|15|7|11|5|10|12|3|4|6 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC(1) 0 SUBFUNCTION = "HPFP SCSI CHANNEL 0 ID" COMMENTS = "This is the primary SCSI channel on the HPFP." HELP = "Jumper 2 should be installed in order to provide termination power to the SCSI bus." CHOICE = "7" FREE INIT = JUMPER(3) LOC(9 10 11) 000 CHOICE = "6" FREE INIT = JUMPER(3) LOC(9 10 11) 100 CHOICE = "5" FREE INIT = JUMPER(3) LOC(9 10 11) 010 CHOICE = "4" FREE INIT = JUMPER(3) LOC(9 10 11) 110 CHOICE = "3" FREE INIT = JUMPER(3) LOC(9 10 11) 001 CHOICE = "2" FREE INIT = JUMPER(3) LOC(9 10 11) 101 CHOICE = "1" FREE INIT = JUMPER(3) LOC(9 10 11) 011 CHOICE = "0" FREE INIT = JUMPER(3) LOC(9 10 11) 111 SUBFUNCTION = "HPFP SCSI CHANNEL 1 ID" COMMENTS = "This channel is only available if the daughter card is installed." CHOICE = "7" FREE INIT = JUMPER(9) LOC(1) 1 INIT = JUMPER(10) LOC(1) 1 INIT = JUMPER(11) LOC(1) 1 CHOICE = "6" FREE INIT = JUMPER(9) LOC(1) 0 INIT = JUMPER(10) LOC(1) 1 INIT = JUMPER(11) LOC(1) 1 CHOICE = "5" FREE INIT = JUMPER(9) LOC(1) 1 INIT = JUMPER(10) LOC(1) 0 INIT = JUMPER(11) LOC(1) 1 CHOICE = "4" FREE INIT = JUMPER(9) LOC(1) 0 INIT = JUMPER(10) LOC(1) 0 INIT = JUMPER(11) LOC(1) 1 CHOICE = "3" FREE INIT = JUMPER(9) LOC(1) 1 INIT = JUMPER(10) LOC(1) 1 INIT = JUMPER(11) LOC(1) 0 CHOICE = "2" FREE INIT = JUMPER(9) LOC(1) 0 INIT = JUMPER(10) LOC(1) 1 INIT = JUMPER(11) LOC(1) 0 CHOICE = "1" FREE INIT = JUMPER(9) LOC(1) 1 INIT = JUMPER(10) LOC(1) 0 INIT = JUMPER(11) LOC(1) 0 CHOICE = "0" FREE INIT = JUMPER(9) LOC(1) 0 INIT = JUMPER(10) LOC(1) 0 INIT = JUMPER(11) LOC(1) 0